The current page does not exist in the target language.

Do you want to change the language and go to the home page or do you want to stay on the current page?

Change Language
SOLAR ENERGY
Installers & partners

Fronius Primo GEN24 Plus

Inverter for private PV systems with PV Point or Full Backup

Our single-phase Fronius GEN24 Plus hybrid inverter is the ideal core for private PV systems. The Fronius GEN24 Plus offers an integrated basic backup power supply with PV Point and even a full backup power solution through the option of connecting a battery storage system.
 
The Fronius GEN24 Plus hybrid inverter enables energy self-sufficiency for electricity, heating, cooling and e-mobility with the use of a battery system. This means that the Fronius GEN24 Plus with Full Backup* has a backup power solutionthat even large consumers can use, such as heat pumps. What’s more, the Multi Flow Technology lets the hybrid inverter supply parallel energy flows in the system, even in backup power mode. 

* Additional external components for grid switchover are required for the Full Backup. More information on this can be found in the operating instructions.
Please choose your desired product.

Product details

INPUT DATA

Number of MPP trackers2
Max. PV input power
3810 W
Max. input current (Idc max)
22 / 12 A
Max. short circuit current, module array*
36 / 19 A
DC input voltage range (Udc min - Udc max)
65 - 600 V
Feed-in start voltage (Udc start)
80 V
Nominal input voltage (Udc,r)
400 V
MPP voltage range (Umpp min - Umpp max)
200 - 530 V
Usable MPP voltage range65 - 530 V
Number of DC connections2+2
Max. PV generator power (Pdc max
5,52 kWpeak

OUTPUT DATA

AC nominal output (Pac,r)
3680 W
Max. output power (Pac max)
3680 VA
Max. grid power demand3680 VA
Max. AC output current23,7 A
Grid connection (Uac,r)
1~ NPE 220/230 V
AC voltage range (Umin - Umax)
155 - 270 V
Frequency (fr)
50 / 60 Hz
Frequency range (fmin - fmax)
45 - 65 Hz
Total harmonic distortion<3% @Pnom (230/400VAC 50Hz)
Power factor (cos φac,r)
0,8 - 1 ind,/cap,
Back-up power1~NPE 220 V / 230 V
Nom. output current (220VAC)
16,7 A
Nom. output current (230VAC)
16 A

GENERAL DATA

Width
474 mm
Height
530 mm
Depth
165 mm
Weight15,38 kg
Weight incl. packaging19 kg
Degree of protectionIP66
Protection class1
Overvoltage category (DC / AC) 1)
2 / 3
Night-time consumption< 10 W
Inverter designTransformerless
CoolingRegulated air cooling
InstallationIndoor and outdoor installation
Ambient temperature range-40°C - +60°C
Permitted humidity0 - 100 %
Max. altitude 2)
4000m
DC PV connection technology4x DC+ and 4x DC- push-in spring terminals 2.5 - 10 mm²
DC battery connection technology1x BATT+ and 1x BATT- push-in spring terminals 2.5 - 10 mm²
AC connection technology3 pole AC push-in spring terminals 2.5 - 10 mm² 3 pole backup power push-in spring terminals 1.5mm² - 10mm² 2x PE-screw terminals 2.5 - 16 mm² and  3x 2,5 - 10mm²
Certificates and compliance with standardsIEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 and 16150, IEC 62116, IEC 61727 8)
Back-up power functionsPV Point, Full Backup 4)
Compatible batteries 6)
BYD Battery-Box Premium HVS/HVM & LG FLEX 5)
Sound emissions42 dB(A)
Interference emission classB

EFFICIENCY

Max. efficiency (PV - grid)97,6 %
European efficiency (ηEU)95,6 / 97,0 / 96,3 (200Vdc / 400Vdc / 530Vdc)
η at 5% Pac,r 3)
85,3 / 90,2 / 87,9 (200Vdc / 400Vdc / 530Vdc)
η at 10% Pac,r 3)
89,5 / 93,2 / 91,5 (200Vdc / 400Vdc / 530Vdc)
η at 20% Pac,r 3)
94,0 / 96,1 / 95,3 (200Vdc / 400Vdc / 530Vdc)
η at 25% Pac,r 3)
94,8 / 96,6 / 96,0 (200Vdc / 400Vdc / 530Vdc)
η at 30% Pac,r 3)
95,4 / 96,9 / 96,3 (200Vdc / 400Vdc / 530Vdc)
η at 50% Pac,r 3)
96,3 / 97,4 / 97,0 (200Vdc / 400Vdc / 530Vdc)
η at 75% Pac,r 3)
96,6 / 97,5 / 97,3 (200Vdc / 400Vdc / 530Vdc)
η at 100% Pac,r 3)
96,7 / 97,5 / 97,3 (200Vdc / 400Vdc / 530Vdc)
MPP adaptation efficiency99,9

PROTECTION DEVICES

DC insulation measurementYes
Overload behaviourOperating point shift. Power limitation
DC disconnectorYes
DC Reverse polarity protectionYes

INTERFACES

WLAN / 2x Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6x digital in/out + 6x digital inInterface to ripple control receiver, energy management
Emergency stop (WSD)Yes
Datalogger and web serverIncluded
2x RS485Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot

OUTPUT DATA PV POINT

Max continuous output power3000 VA
Nom. output current (Iac max)
13 A
Grid connection1 ~ NPE 220 V / 230 V
Frequency50 Hz / 60 Hz
Max. switchover time PV-Point23 s
Max. switchover time Full Backup35 s
Frequency in backup power mode53 Hz

BATTERY CONNECTION

Number of DC connections1
Max. input current (Idc max.)
22 A
DC input voltage range (Udc min - Udc max)
150 V - 455 V 7)
Max. input / output power (Depending on the connected battery)3810 W
Max. AC charging power (Depending on the connected battery)3680 W
Min. DC input voltage150 V
Max. DC input voltage455 V

Integrated data communication

We are the first inverter manufacturer to offer a data communication package with fully integrated datalogging, WLAN, Ethernet, energy management, web server and a range of interfaces. The inverter is connected to the internet by network cable or WLAN - without additional cabling - and grants you the perfect overview of how the PV system is operating. Connection to third-party components is provided by means of interfaces such as Modbus TCP SunSpec, Modbus RTU SunSpec or Fronius Solar API (JSON). The open interfaces can also be operated in parallel to the Fronius Solar.web.

Dynamic Peak Manager

The Dynamic Peak Manager is a new MPP tracking algorithm that dynamically adapts its behaviour when searching for the optimal operating point. Its special feature is that the Dynamic Peak Manager automatically checks the entire characteristic curve on a regular basis and finds the global Maximum Power Point (GMPP), even in partial shade.

Multi Flow Technology

Using Multi Flow Technology, different DC and AC energy flows are possible in parallel. On the one hand, this allows energy from the modules and from the battery to be made available for domestic use at the same time. However, it is also possible for the energy from the modules to be simultaneously fed into the battery and the in-house network. Furthermore, not only can the battery be charged from the DC side, but also from the AC side (for example from existing PV systems or other energy sources, such as a wind turbine). This means the inverter is also suitable for AC-coupled retrofitting. The inverter manages these energy flows in such a way that the highest possible degree of self-sufficiency is achieved.

SuperFlex Design

The Fronius SuperFlex Design is an ingenious combination of technical performance attributes that make designing your PV system not only extremely simple, but also incredibly flexible. The key performance factors of the SuperFlex Design are two MPP trackers, together with a high system voltage and wide DC input voltage range. Every DC input, and therefore every MPP tracker, is able to accommodate the entire nominal output of the inverter. Regardless of whether the inverter has to cope with different roof orientations, shading of one or two strings, or the use of residual modules: a Fronius inverter featuring integrated SuperFlex Design will satisfy every conceivable operational PV system planning scenario using just a single inverter model.

full backup

With the full backup option, the entire household, i.e. 1 phase as well as 3 phase devices, can be supplied with electricity in the event of a grid outage. For Full Backup, a battery and a switching device for safe grid disconnection are required in addition to the inverter.

PV Point

The integrated basic grid back-up - a socket that is supplied with power during power outages - ensures that important loads can conitunue to operate should the power fail.

Active Cooling

Active cooling technology relies on one or more fans, which not only avoid hot spots, but also regulate the air circulation inside the inverter, thus keeping the temperature of the power electronics low. This has a positive effect on the service life of the devices, optimises yields and reduces costs. At Fronius, active cooling is supplied as standard in all devices.
More information about the features of this product
Clear HTML version of the operating instructions. Mobile and optimised  for every device.
Information for installation and commissioning

Downloads

Show all downloads for product

FOOTNOTES FOR TECHNICAL DATA

1) According to IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK 

2) Unrestricted voltage range.

3) At Umpp min. / Udc,r / Umpp max.

4) Depending on the connected battery.

5) This does not apply to the BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1 & LG RESU FLEX 17.2

6) Depending on the country-specific certification and availability

7) An AC power derating of the inverter occurs from a battery DC input voltage of 419.7 V

8) You can find the current certificates under www.fronius.com/primo-gen24-plus-cert 

 

* Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g.: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.